Low Frequency Electromagnetic Technique LFET

1.Super Heater , Water wall, Re-heater and economizer tubing in utility Boiler tube
2. Inspection performed from OD side flaw can detected both OD & ID
3. Both magnetic and non-magnetic scanned

4. Detects flaws, including corrosion cells and hydrogen damage, caustic and phosphate gouging, oxygen pitting, departure from nucleate boiler, ID pitting, corrosion, and erosion.
5. Tank floor also scanned